DIU 220  
FEATURES  
Power over Ethernet Door Interface Unit  
• Ethernet communications and  
OVERVIEW  
power via a single Cat5/6 cable  
The DIU 220 (PoE Door Interface Unit) combines Ethernet communications and  
sufficient power to support a complete door set, including an In reader, Out reader and  
a standard 650mA maglock, over a single Cat5/6 cable. The DIU 220 eliminates the  
need to include a power supply unit (PSU) at the door and expense of providing mains  
power to the PSU.  
• Eliminates to need to have mains  
power and a PSU at the door  
• Provides local power for:  
In reader  
Out reader  
The DIU 220 is designed primarily to provide power to a door lock, as well as local  
power to a CEM reader when a high level of security is required. It has onboard  
inputs which can be used to monitor conditions such as a fire alarm or activated  
break-glass condition.  
Maglock  
Sounder  
Door Holder  
The DIU 220 improves door security by allowing the installer to locate lock controls on  
the secure side of a door, with an intelligent CEM reader on the unsecured side. The DIU  
220 communicates with an intelligent CEM reader via the readers slave communication  
channel. Upon a valid swipe at the card reader, the reader will instruct the DIU (over  
the communications channel) to activate the appropriate output to release the lock  
using a coded data signal (i.e. coded lock).  
• 11.5V @ 1.6A power output*  
• Door Interface Electronics held on  
one board  
• Provides ‘coded lock’ interface  
between door hardware and  
card reader  
As an added benefit, the DIU 220 monitors the status of all standard door monitoring  
inputs; inputs on an intelligent CEM reader are free for use as general purpose inputs.  
The DIU 220 is supplied in a plastic enclosure complete with PoE backplane and an  
output for an additional door holder.  
• Fire alarm and break glass inputs  
for emergency door and holder  
release  
• Weigand interface for 3rd party  
exit reader.  
• Designed for ease of installation  
and maintenance using 2 part  
connectors throughout  
• Compliant with EN55022  
(emissions) and EN55024 (access  
control immunity)  
o
o
* 1.6A @ 23 C or 1.4A @55 C  
DIU 220  
 

Tatung Home Theater Screen TBM 0903 User Manual
Taylor Scale 3804 44 User Manual
Technicolor Thomson CRT Television 14MH10C User Manual
Technika Flat Panel Television LCD 40 270 User Manual
Teledyne Respiratory Product 3300ZB User Manual
Toshiba Security Camera IK HD3D User Manual
Tripp Lite Power Supply APS1024INT User Manual
Uniden Cell Phone TCX930 User Manual
Uniden Cordless Telephone WXI3077 User Manual
Uniden Scanner UBC144XLT User Manual